MANUFACTURE AND CHARACTERIZATION OF INDICATOR ELECTRODES FROM PPy + H2SO4 AND PPy + SULFONIC ACID AS A UREA SENSOR USING UREASE ENZYME IMMOBILIZATION TECHNIQUE IN PVA

Hakim S., Abdul and Rianna, Martha and Rais, Abdul (2023) MANUFACTURE AND CHARACTERIZATION OF INDICATOR ELECTRODES FROM PPy + H2SO4 AND PPy + SULFONIC ACID AS A UREA SENSOR USING UREASE ENZYME IMMOBILIZATION TECHNIQUE IN PVA. Materials Science for Energy Technologies, 06. pp. 89-93. ISSN 2589-2991

[thumbnail of Fulltext.pdf]
Preview
Text
Fulltext.pdf - Published Version

Download (696kB) | Preview
[thumbnail of Turnitin.pdf]
Preview
Text
Turnitin.pdf - Published Version

Download (560kB) | Preview
[thumbnail of Koresponden Journal.pdf]
Preview
Text
Koresponden Journal.pdf - Published Version

Download (1MB) | Preview
[thumbnail of KORESPONDENSI_Abd Hakim. S.pdf]
Preview
Text
KORESPONDENSI_Abd Hakim. S.pdf - Published Version

Download (2MB) | Preview

Abstract

esearch has been carried out on indicator electrodes (1) PVA-Enzyme/PVC-KTpClPB, sensitivity 19,069 mV/decade, detection range 1.10−5–5.10−4 M, detection limit 1.10–5 M. The width of the peak UV–vis absorbance is narrow (2) PVA-Enzyme/GA-2.9 %/PVC-KTpClPB wide UV–vis absorbance peak but the absorbance peak decreased, (3) PVA-Enzyme/GA-2.9 %/PVC-KTpClPB-o-NPOE XRD analysis amorphous spectral pattern appeared (4) PVA-Enzyme/GA-2.9 %/PPy + H2SO4/PVC-KTpClPB-o-NPOE (5) PVA-Enzyme/GA-2.9 %/PPy + Sulfonic Acid/PVC-KTpClPB-o-NPOE, amorphous spectrum pattern in (4) and (5) were greatly reduced for the enzyme variation of 0.6 g in 0.5 mL (50 % water + 50 % alcohol). GA plays a role in increasing the detection range, o-NPOE forms amorphous, enzyme variations increase the intensity of the XRD spectrum pattern. The method of developing a gradual modification of the indicator electrode membrane by cross-linking GA, o-NPOE, conductive polymer. The best results were obtained at the indicator electrode PVA-Enzyme/GA-2.9 %/PPy + Sulfonic Acid/PVC-KTpClPB-o-NPOE. Analysis of the linear curve of the sample EI5-1 with a sensitivity of 41.56 mV/decade, a detection range of 10−4–10−1 M and a detection limit of 10−4 M, R2 = 97.51 %. The best indicator electrode is EI5-1.

Item Type: Article
Keywords: Sulphonic acid; Biosensor potentiometry; Immobilization; Urease enzyme
Subjects: Q Science > QC Physics
Q Science > QC Physics > QC170 Atomic physics. Constitution and properties of matter including molecular physics, relativity, quantum theory, and solid state physics
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Pendidikan Fisika
Depositing User: Mrs Harly Christy Siagian
Date Deposited: 13 Dec 2022 06:49
Last Modified: 07 Mar 2023 08:19
URI: https://digilib.unimed.ac.id/id/eprint/49576

Actions (login required)

View Item
View Item