CHARACTERIZATION OF MANUFACTURING INDICATOR ELECTRODES COATED PVA-ENZYME COATED 1X GA AND 3X GA 2.9% COATED PVC-KTpClPB COATED USING POTENTIOMETRY METHOD

Hakim S., Abdul and Mihardi, Satria and Rais, Abdul and Willy and Panjaitan, Y. T. H (2022) CHARACTERIZATION OF MANUFACTURING INDICATOR ELECTRODES COATED PVA-ENZYME COATED 1X GA AND 3X GA 2.9% COATED PVC-KTpClPB COATED USING POTENTIOMETRY METHOD. In: The 1st International Conference Science Physics and Education (ICSPE 2021), 10-11 Sept 2021, Mataram.

[thumbnail of Fulltext.pdf]
Preview
Text
Fulltext.pdf - Published Version

Download (516kB) | Preview
[thumbnail of Reviewer.pdf]
Preview
Text
Reviewer.pdf - Published Version

Download (279kB) | Preview
[thumbnail of Turnitin.pdf]
Preview
Text
Turnitin.pdf - Published Version

Download (1MB) | Preview

Abstract

Research has been carried out on the manufacture of tungsten indicator electrodes with a diameter of 1 mm coated with PVA-Enzyme coated with PVC-KTpClPB using the biosensor potentiometer method. It has a sensitivity of 19,096 mV/decade, a detection range of 1.10-5 - 5.10-4 M, a detection limit of 1.10-5 M and a correlation coefficient of R2 = 0.9431. This detection range is very small, only a difference of one order to the negative power. On the basis of this small range, the PVA-Enzyme and PVA-Enzyme-GA solutions have been characterized by UV-vis showing a very clear difference in the width of the absorbance peak at wavelength. The indicator electrodes B1-4 and B3-4 have been analyzed using UV-vis, FTIR, SEM-eds and XRD. The method used is the biosensor poteniometric method, urease enzyme immobilization technique, which analytes urea in determining sensitivity, detection range and detection limit, as well as variable signal analysis of 60 signals/second. The results obtained from the indicator electrode B1-4 have a sensitivity of 46.67 mV/decade, a detection range of 10-4 - 10-2 M and a detection limit of 10-4 M, R2 = 99.62 %. The indicator electrode B3-4 has a sensitivity of 38.16 mV/decade, a detection range of 10-6 - 10-4 M and a detection limit of 10-6 M, R2 = 95.42 %. The best results on electrodes B1-4.

Item Type: Conference or Workshop Item (Paper)
Keywords: Electrode; Potentiometric biosensor; Immobilization
Subjects: Q Science > QD Chemistry > QD450 Physical and theoretical chemistry
Q Science > QD Chemistry > QD71 Analytical chemistry
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika
Depositing User: Mrs Harly Christy Siagian
Date Deposited: 29 Jul 2022 09:49
Last Modified: 29 Jul 2022 09:49
URI: https://digilib.unimed.ac.id/id/eprint/47029

Actions (login required)

View Item
View Item